Related Products

2m/s low wind speed starts the wind turbine generator.
This is the most obvious advange of this wind generator in all of same level product on the market which make high wind energy utilization rate.
Low fault and strong ability to resist the Typhoon
Fan adopts the unique design of the fuselage shock smooth operation, no noise, the blades with nylon composite materials manufacturing and become, with the optimization of aerodynamic design and structural design, start wind speed is low, high wind energy utilization coefficient, increase the power generating capacity. Stern rudder adopts the design of automatic yaw, stronger ability to resist the typhoon, safe and reliable operation.
Horizontal shaft function.
The wind turbine generator can adjust the angle automatically according to the wind directions by the horizontal shaft design.
20-year long service life.
Due to the motor internal labyrinth design, external all fasteners are high strength stainless steel products, so it has better protection effect, can waterproof (IP65), prevent sand more effectively.
Easy Installation
Tech Parameters
!!! If you only Wind Turbine Generator —-link ( 600W )to order !!!
Rated power | 600W |
Maximum power | 830W |
Rated voltage | 12/24V AC |
Start-up wind speed | 2.0m/s |
Rated wind speed | 12m/s |
Survival wind speed | 50m/s |
Top net weight | 10kg |
Wheel diameter | 1.4m |
Number of blades | 5 |
Blades material | Germany Nano nylon glass fiber |
Generator type | Three phase permanent magnet AC synchronous generator |
Magnet material | NdFeB |
Generator case | Casting aluminum alloy |
Control system | Electromagnet/wind wheel yaw |
Speed regulation | Automatically adjust windward direction |
Working temperature | -50 to 60 degree |
Design life | 20 y |
Packing Size | 78x42x26cm |

1. The Wind Turbine Generator charging part and Solar charging part are independent with each other, which means that can separately use as Wind Turbine Controller or Solar Controller;

|
800W Wind & 400W Solar | 600W Wind & 400W Solar | 500W Wind & 300W Solar | ||||
System Rated Voltage |
12V/24V Auto-work | ||||||
Solar Panel PV Modules Power |
400W | 400W | 300W | ||||
Wind Turbine Generator Power |
800W | 600W | 500W | ||||
Charging |
Max. Current |
80A | 65A | 50A | |||
Average Filling Protection |
14.4V±1% / 28.8V±1% | ||||||
Float Filling |
13.8V±1% / 27.6V±1% | ||||||
Average Filling Recovery |
13.2V±1% / 26.4V±1% | ||||||
Temperature Compensation |
-24mV/℃ / -48mV/℃ | ||||||
Discharging |
Disconnect (dc) |
10.8V±1% / 21.8V±1% | |||||
Recovery (dc) |
12.3V±1% / 24.6V±1% | ||||||
Over Voltage |
Cut Off (dc) |
16V±1% / 32V±1% | |||||
Recovery (dc) |
15V±1% / 30V±1% | ||||||
Idle Current (dc) |
≤0.1A | ||||||
Voltage Drop (dc) |
≤0.5V | ||||||
Control Mode |
MPPT charge function, PWM unload function, PWM flow current limiting function | ||||||
Booster Charging |
Flexible independent booster circuit (optional) | ||||||
Display Parameters |
Voltage, charging electric current, storage battery power | ||||||
Display Way |
LCD | ||||||
Protection Type | Lightning protection; Solar reverse charge protection; Battery open-circuit protection; Battery reverse protection; Over wind speed and over-voltage soft automatic brake protection; Overload protection; etc. | ||||||
Cooling Mode |
radiator | ||||||
Environment Temperature |
-25℃~+55℃ | ||||||
Use altitude |
≤5500 m (2000 m above the need to reduce power use) | ||||||
Environment Humidity |
0~90%, not knot de | ||||||
Weight |
1.15KG | ||||||
Shape Dimension |
165*140*64mm |